2 JOHNSON CONTROLSģ FORM RP4 (809) TABLE OF CONTENTS PAGE UNIT NOMENCLATURE NAMEPLATE ENGINEERING DATA.4 EVAPORATOR HEAT EXCHANGER AND RELATED COMPONENTS.5 CONDENSER COILS CONDENSER COIL COMPONENTS.8 FAN FAN COMPONENTS.2 PIPING REFRIGERANT PIPING COMPONENTS.4 COMPRESSOR COMPRESSOR.24 CONTROL AND POWER PANEL CONTROL PANEL AND POWER PANEL CONFIGURATIONS.28 CONTROL PANEL AND POWER PANEL COMPONENTS.29 CONTROL WIRING HARNESSES.57 SENSOR WIRING HARNESSES.58 TEMPERATURE SENSORS AND TRANUCERS.60 TRANUCER AND THERMISTOR WIRE HARNESS CONNECTORS.62 ENCLOSURE UNIT ENCLOSURE COMPONENTS.64 CHILLER OPTIONS VIBRATOR ISOLATORS.68 CHILLER OPTIONS.69 PUMP PACKAGE KIT OPTIONS.70 ENCLOSURE KIT OPTIONS.82 OPTIVIEW REMOTE CONTROL CENTER.88 REMOTE CURRENT/TEMPERATURE RESET PARTS BREAKDOWN.89 RECOMMENDED SPARE PARTS.90 JOHNSON CONTROLS 3Ĥ FORM RP4 (809) UNIT NOMENCLATURE NAMEPLATE ENGINEERING DATA BASIC PART NUMBER YCAL006EC28XDA BASE PRODUCT TYPE NOMINAL CAPACITY UNIT DESIGNATOR REFRIGERANT VOLTAGE/STARTER DESIGN/DEVELOPMENT LEVEL Y : YORK # Tons/Kw E High Efficiency C :R-22 7 :200/3/60 D C : Chiller :230/3/60 A : Air Cooled L : Scroll to :380/3/60 :460/3/60 A 5 0 :385-45/3/ :575/3/60 X :Across the Line :Design Series D :Engineering Change or PIN Level PART NUMBER LETTER CODES POWER FIELD CONTROLS FIELD COMPRESSOR / PIPING FIELD S S B X D X T C : SP Terminal Block L : SP NF Disconnect Switch H : SP Circuit Breaker A : Transformer 5/24V (factory) : Power Factor Capacitor MP = Multiple Point SP = NFDS = Non-Fused Disconnect Switch TB = Terminal Block Ser. Voltages as low as 50 volts may cause death. LOW VOLTAGE DO NOT be misled by the term low voltage. Be careful not to contact high voltage connections when installing or operating this equipment. When working inside equipment with power off, take care to discharge every capacitor likely to hold dangerous potential. Shut off power supply to the equipment before beginning work and follow lockout procedures. Work on electronic equipment should not be undertaken unless the individual(s) have been trained in the proper maintenance of equipment and is (are) familiar with its potential hazards. DEATH OR SERIOUS INJURY may result if personnel fail to observe safety precautions. WARNING HIGH VOLTAGE Is used in the operation of this equipment. If there is any question in the mind of operating/ service personnel as to the applicability of these documents, then, prior to working on the equipment, they should verify with the owner, whether the equipment has been modified and if the current literature is available. It is the responsibility of operating/service personnel as to the applicability of these documents to the equipment in question.
York ycal parts list update#
While YORK makes no commitment to update or provide current information automatically to the manual user, that information, if applicable, can be obtained by contacting the nearest YORK Engineered Systems Service office. 1 AIR-COOLED LIQUID CHILLERS HERMETIC SCROLL RENEWAL PARTS Supercedes: RP4 (206) Form: RP4 (809) MODELS YCAL002, 008, 002, 0025, 0027, 0032, 004, 0045, 005, 0055, 006, 0065, AND YCAL007 STYLE "D" 29302A 2-70 TON Kw 50Hz and 60Hz / MODELS ONLYĢ FORM RP4 (809) CHANGEABILITY OF THIS DOCUMENT In complying with YORK's policy for continuous improvement, the information contained in this document is subjected to change without notice.